Tester

CALPRO

We use higher order reference method calibrators and all of our testing and calibration devices are certified by third party to meet the Malaysia Standards MS 2058 edition: 2009 Code of Practise for Good Engineering Maintance, Management of Active Medical Devices. 

 

Most regulatory agencies suggest recalibration of a unit’s pressure readings but due to the technical constraints, the unit can only be recalibrated by manufacturer via sophisticated equipment.

 

Knowing the importance of recalibration to the units and the users, Rossmax devoted 2 years to develop the world’s first mobile calibration system. Simply connect Rossmax BPM to CalPro, with its intuitive operation, now the recalibration is only a matter of seconds. The calibration system developed by Rossmax can check the accuracy of the unit’s pressure reading, recalibrate the BPM device when the reading is out of calibration and check / reset the usage record of the unit. CalPro can also serve as a pressure gauge. The acceptable allowance is within ± 3 mm Hg.

 

 

 

 

Certification

Certificate Of Calibration

 

 

THERMOCAL

Accuracy is always the biggest concern of a thermometer user. Rossmax ThermoCal is a portable and convenient device that allows our biomedical engineers to easily check the accuracy of a thermometer in just a few seconds. The innovative design of the adjustable blackbody cavity applies to all three types of Rossmax thermometer products – pen type, ear and forehead thermometer. Thermometer will beep when the measurement is completed. Compare the reading given by the thermometer to the calibration temperature. The acceptable allowance for forehead & ear thermometer is within ± 0.2°C. For pencil thermometer is ± 0.1°C

 

  •  Check the accuracy of thermometer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Certification

Certificate Of Calibration

 

NEB TESTER

The Rossmax Neb Tester is a portable and easy-to-use device that allows our biomedical engineers to quickly check the performance of the pump of a compressor nebulizer. No power source is required for the Neb Tester to operate and the test result is easy to read and interpret. This device is used to simulate the working conditions of the pump when the nebulizer is in operation with a medicationcup. For checking the following performances – Maximum (“free”) Air Flow, Operational Air Flow at particular pressure and Maximum Air Pressure. For the acceptable air flow, NB80 must ≥3.0 L/min when pressure at 8.0psi and NB500 must ≥ 3.5 L/min when pressure at 15.0psi.

 

For checking:

  • Maximum (“free”) air flow
  • Operational air flow at particular pressure
  • Maximum air pressure

 

 

 

 

 

Certification

Certificate Of Calibration

Certificate Of Calibration

 

SUCTION TESTER

Rossmax Suction Tester is a portable and easy-to-use device that allows our biomedical engineers to quickly check the performance of the pump of a suction unit. Power source is not required for Suction Tester during operation and the test result is easy to read and interpret. Suction Tester consists of an oil vacuum gauge, flow meter, PVC tubing and stainless steel stand. This device is used to check the working conditions of the pump. For checking the following performances – Maximum (free) air flow – Air flow scale 0~50 L/min accuracy ±4% of full scale and Maximum vacuum – Vacuum scale 0~-76 cmHg accuracy ±2.5% of full scale.

 

Certification

Certificate Of Calibration

 

PROSIM SPOT LIGHT SPO2 PULSE OXIMETER ANALYZER

Featuring an exclusive ergonomic design, the ProSim SPOT Light is the first comprehensive SpO2 pulse oximeter analyzer to come in a handheld and easy-to-use device. SPOT Light is lightweight and flexible with three custom presets specially-designed to make it the fastest and easiest-to-use pulse oximeter analysis device on the market today for SpO2 functional testing. A helpful LCD display and three simple buttons make it effortless to rapidly change parameters and view each signal output sent to the pulse oximeter at a glance.

 

 

Certification

Certificate Of Calibration

 

 

FIXED WEIGHT

All weighing and measuring instruments use for trade need to be verified first before use and re-verified once every twelve months thereafter as stipulated by the Weight and Measures Act 1972 by The Metrology Department Malaysia (MDM). Our biomedical engineers would use the Fixed Weight which was certified by the Department to check the accuracy of the scales before returning to customers. It is an offence to use weighing or measuring instrument without valid verification or re-verification by MDM. The acceptable allowance below 100kg is 0.4kg (± 400gram) and above 100kg is 0.5kg (± 500 gram)

 

Certification

Certificate Of Calibration